Command stations: scope and evidence
This overview separates implemented functions from documented device acceptance. It describes v0.3.0; older releases may differ. Recaptured handbook pictures do not add hardware acceptance. The device evidence below retains its own review scope.
Functions by connection
| Connection | Reading and comparison | Writing to the station | Locomotive images |
|---|---|---|---|
| ECoS | Locomotive data, static functions, comparison worklist; stored CV1–1024 cache | Confirmed locomotive-data writes; no CV programming | Preparation, download and confirmed upload/assignment |
| CS3 / CS3 Plus | Roster UID, name, address and protocol; no CVs | Unavailable | Prepare PNG and import manually on CS3 |
| Z21 / z21 | Test, diagnostics and bounded address comparison for known RailKeeper addresses | Unavailable | Prepare PNG for the Z21 app; no image storage in the station |
| Intellibox 3 | Test and diagnostics using Z21-compatible UDP | Unavailable | Prepare PNG for IB3 Configuration; no direct RailKeeper upload |
A readable reply or suitable image dimensions do not establish successful operation on every model. Image export and direct upload are separate capabilities.
Recorded device evidence
| Device / firmware | Evidence | Remaining boundary |
|---|---|---|
| ECoS, application firmware 4.3.3 | Recorded locomotive-data write acceptance after PR #143; later user-confirmed image export, upload and automatic assignment | Does not establish a full model/hardware matrix; no anonymized raw-response fixture was retained for that earlier acceptance |
| ECoS 4.3.3, busy locomotive control | One authorized protocol probe confirmed error 25 when control was occupied | The revised pre-upload reservation, deduplication and pause/resume order has automated/simulated coverage; additional device acceptance remains open |
| Other ECoS firmware | Complete compatible identification replies can be used as not device-verified | No blanket acceptance of all firmware versions |
| CS3, pre-2.6 and 2.6+ API shapes | Parser/regression tests based on modeled compatible response forms | No direct complete RailKeeper hardware acceptance recorded |
| Z21 / z21 | Protocol-based UDP fixtures and automated tests | No recorded physical model/firmware acceptance of these read workflows |
| Intellibox 3 | Automated Z21-compatible transport tests | Physical Intellibox acceptance pending; LocoNet over TCP is planned, not implemented |
The image dialog's ECoS 50200/50210/50220 labels identify the intended output format. They do not establish three separate hardware acceptances. New handbook images show an isolated demo. Simulated station replies are explicitly labelled in the image guide.
What does connection status mean?
| ECoS result | Meaning and next step |
|---|---|
| Unreachable or rejected | Check address, server reachability, port and error |
| Partial | Required identity fields or end marker are missing; do not activate |
| Not device-verified | Complete reply, but no recorded acceptance for this firmware |
| Device-verified | Firmware matches the recorded acceptance; edge cases retain their own evidence limits |
Ping or web access does not replace the protocol test. ECoS needs TCP 15471 and additionally HTTP 80 for images. CS3 uses its configured HTTP port; Z21 and Intellibox 3 default to UDP 21105.
Contribute another device acceptance
Record model, hardware revision, firmware, RailKeeper version, transport and exact workflow. Record expected and actual results, including interruptions and conflicts. Keep captures limited to necessary fields and remove personal information. Device writes need explicit authorization; connection checks begin read-only.
